EP6000 series electrical and gas valve locator

Products > Valve positioner > EP6000 series electrical and gas valve locator

EP6000 series electrical and gas valve locator

1, Suitable for small capacity and large capacity of actuators.
2, Amplifier, gas consumption is small, large capacity.
3, Can choose the output characteristic.
4, Single-acting actuator in need reaction control, positive action type amplifier is
easy to transform into a reaction type amplifier.
5, Pressure explosion-proof type can be adjusted in the field.
6, Intrinsically safe has a broad scope of the structure of the building.
Contact purchase
shared:

First, Product Overview
EP6000 series of electric valve positioner and actuator, 4 ~ 20 mA DC input the  signal output of air pressure, the control action of the actuator. At the same time  according to the stroke of the actuator feedback, so that the actuator stroke can  accurate positioning according to control signal. EP6000 series electric valve  positioner can be used for single action and double action type actuator.

Second, Technical Data

SeriesEP6000
Input signal4-20mA DC
Process control can be carried out
Adjustment range:4-12、12-20mA DC
Input impedance250Ω~±5% at 25℃
Output characteristicLinear (standard)
AmplifierSingle action type actuator and double action type actuator combination, single action is action type
amplifier is easy to transform into a reaction type amplifier (input signal increases, the output pressure decreases).
Air pressure0.14-0.7MPa(140-700KPa)
Output pressure0-0.7MPa(0-700KPa)
Air consumptionThe output 50% air pressure gas consumption.
Single acting type:  5NI/min at 140KPa air supply
Double acting type:  15NI/min at 400KPa air supply
The biggest processing capacityWhen the output side air vent
Single acting type:175NI/min at 140KPa air supply
Double acting type:400NI/min at 400KPa air supply
PerformanceSingle action type actuator
Linearity ................±1.0% of Full stroke
Hysteresis ................0.5%of Full stroke
Response ................0.1% of Full stroke
Repeat accuracy .............0.2% of Full stroke
Air pressure change of error ....0.1% /10KPa
Double action type actuator
Linearity ................±1.5% of Full stroke
Hysteresis ................0.8% of Full stroke
Response ................0.2% of Full stroke
Repeat accuracy.............0.3% of Full stroke
Air pressure change of error ....0.4%/10KPa
The above represents the performance of the positioner on an actuator without a valve.
Air supply connectionRC1/4
Power interfaceNPT1/2(G1/2)
Environment temperatureStandard type:-20~80℃
Humidity range10~90%RH
Structure formOutdoor waterproof type (increased safety type) e Ex eⅡT6 Gb,IP65
Pressure explosion-proof (flameproof type)d Ex dⅡBT6 Gb
Intrinsically safe type (intrinsic safety type)i Ex iaⅡCT6 Gb
Subsidiary bodyAuto,Manual change
Shell materialAluminum alloy
Surface coatingSpray plastic
Standard coating colorBlack  Lightgray  Blue
Weight2.3Kg-3Kg
Additional specificationsAccording to the customer request production
Electrical interface1/2NPT (Outdoor waterproof type)
Pressure filler type (Pressure explosion-proof type)
Seal joint type (Pressure explosion-proof type)
Safety barrierZener safety barrier(Ex iaⅡC)
Pressure gauge calibrationMPa、KPa、Bar、Psi
CharacteristicEqual percentage
Air interface1/4NPT


Third, Model Specification

EP6   0     0     0     0     0   

ModelExplosion-proof grade
(protection) structure
Feedback (action)Action typeAccessories
EP6 1 Flame proof d Ex
dⅡBT6 Gb
 1   Straight travel actuators:standard
 1 Single action with
actuator (single-acting)
 b    AS  
With correlation
matching combination
Air filtering pressure
reducing valve
 2 Increased safety type
e Ex d ⅡT6 Gb, IP65
 2 Quarter-turn
actuators:standard
 2 Double action with
actuator(double-acting)
 3 Intrinsic safety type
I Ex iaⅡC T6 Gb


  

Example: EP3111: said flameproof, straight trip, single function
EP3322: it means the Ann model, Angle, dual role

When ordering, please specify: 1, Type;  2, Input signal;  3, Gas supply pressure;  4, Output characteristic;  5, With pressure reducer;
6, Stroke;  7, The actuator specifications;  8, Output pressure.